Access
3-188 G24-L AT Commands Reference Manual April 15, 2008
The following table shows the +EMPC parameters.
Command
Type Syntax Response/Action Remarks
Set
+EMPC=<pin>,<action> +EMPC:<unlock>,<reset>
OK
or:
+CME ERROR: <err>
The Set command checks the
password with requested action
type. All parameters are
mandatory field. If the pin is
wrong or inserts wrong action, no
action is taken towards the G24-L,
and an error message, +CME
ERROR, is returned to the
terminal. The Set command issued
gives the code corresponding to
the required action.
Read
+EMPC? +EMPC:3,<reset>
OK
or:
+CME ERROR <err>
The read command returns the
current EMPC reset value only.
Table 3-125: +EMPC Parameters
<Parameter> Description
<pin> Subsidy Lock pin code.
<action> 0 Unlock subsidy
1Reset subsidy
<unlock> 0 Correct pin code is entered
1 Wrong pin code is entered
2Wait
3 No meaning
<reset> 0 No subsidy lock
1 Subsidy lock / Reset not allowed
2 Subsidy unlock / Reset allowed