Modem Configuration and Profile
3-194 G24-L AT Commands Reference Manual April 15, 2008
S, Bit Map Registers
This command reads/writes values of the S-registers. The G24-L supports this command for
various S values, according to official specifications (ITU-I, ETSI, or manufacturer specific).
Command Type Syntax Response/Action Remarks
Set
ATSn=<value> OK
or:
+CME ERROR: <err>
The Set command is allowed for
read/write S-registers, and not allowed
for read-only S-registers.
Read
ATSn? <current value of
S-register n>
or:
+CME ERROR: <err>
Test The Test command for Sn is not
defined by ITU, and therefore is not
supported by the G24-L. The G24-L
returns an error.